MistraSwitch


MistraSwitch NG 

Column Selection - Temperature Controlled
Fully Automated
Temperature Controlled
Column Selection for up to
9 HPLC/UHPLC Columns + Bypass


MistraSwitch NG2 and NG3 
temperature controlled column selector 

The MistraSwitch NG system solution is designed for fully automated selection for up to 9 HPLC + bypass or UHPLC columns (up to 15kpsi) or 5 UHPLC columns + bypass (up to 15kpsi) under temperature control using a Jasco CO 4060 or CO 4065 column thermostat. The system consists of the MistraSwitch NG valve box which is equipped with two MayLab MS 6000 valve drives, and the MS 6000 NG interface.

Software drivers for chromatography data systems must be ordered separately.



MistraSwitch NG Features Summary
  • Separate electrical heating and peltier cooling
  • Temperature range from 5°C up to 90°C Column Holder for up to 9 columns (each 25cm length) with “snap in” clamps
  • Door Sensor
  • Separate Leakage and Gas Sensor
  • Unrivalled temperature stability and –precision (both values better than 0.1°C)
  • Valve switching speed less than 100 ms
  • Patented microprocessor controlled valve actuating
  • USB control
  • Very rugged, reliable and laboratory proven construction

MistraSwitch NG Interfacing
Chromatography Data Systems


Fully automated temperature controlled column selection within a chromatography data system is the most efficient way for unattended and overnight operation when using different methods with different columns and temperature.

Software drivers are available for:

  • Agilent ChemStation 16 bit and 32 bit
  • Agilent EZChrom Elite V 3.1.4 and higher
  • Dionex Chromeleon V 6.4 and higher
  • AB Sciex Analyst V 1.4.1 and higher (tested up to version 1.7)
  • Thermo Scientific ChomQuest V 4.1 and higher
  • Thermo Scientific Xcalibur V 1.4 and higher (tested up to version 4.0)
  • Agilent EZChrom Elite V 3.1.4 and higher

The drivers named above are designed to report every error (e.g. faulty valve)
through message boxes and will stop the actual running method immediately.

MistraSwitch NG and GLP
(Good Laboratory Practice)

Both MS 6000 valve drives are selecting the column at exactly the same time. The actual column position is constantly being reported to the MS 6000 NG Interface and to the driver software. The actual oven temperature is also constantly being reported to the software.
Each switching cycle is recorded in a log file, including action, time and date stamp due to GLP reasons for each day. By this means the systems activities will be manageable and reproducible for the operator.

MistraSwitch NG and Valve Configuration

For column selection two of the approved VICI Cheminert high (up to 15000 psi) pressure valves with 1/16” fittings and 0.25 mm port diameter are used in combination with two MayLab MS 5000 valve drives and the MS 6000 Interface in synchronous operation.
This unique column selection on the column in and output decreases carry over and increases the system´s performance.

The MistraSwitch NG system solution is available for selecting 5 (MistraSwitch NG2), or 9 (MistraSwitch NG3) UHPLC columns for up to 15000psi.



Included in Delivery

The MistraSwitch NG system solution comes as a ready to use system and consists of the following items:
  • Valve box with two MS 6000 valve drives with 6 or 10 port VICI valves
  • MS 6000 NG (Versatile MayLab HPLC valve controller
  • CO 4060 Column thermostat
  • PEEK or stainless steel Fittings for VICI Cheminert valve 
  • RS 232 cables for connecting MS 6000 interface and thermostat to valve box
  • Cables for connecting the valve box to MS 6000 interface
  • USB cable for connecting MistraSwitch NG to computer
  • Instruction Manual

MistraSwitch NG Ordering Codes
Download
MistraSwitch NG Brochure
Download
MistraSwitch NG2 - NG3 Hardware User´s
Manual
Download
Share by: